2. Install retaining screws and tighten to 4.5-7.0 Nm (44-61 in lb).
3. Apply Silicone Dielectric Compound D7AZ-19A331-A (Motorcraft WA-10) or equivalent meeting Ford specification ESE-M1C171-A to all

ignition wire boots.

4. Install each ignition wire connector to the proper terminal on the ignition coil. Make sure boots are fully seated.
5. Connect fuel charging wiring to the ignition coil and radio ignition interference capacitor.