Starter Motor: Service and Repair

NOTE:  If the starter motor is noisy or if it locks up, loosen the mounting bolts enough to hand fit the starter properly into the pilot plate before
replacing the starter. Tighten the mounting bolts, starting with the top one. 

1. Disconnect battery ground cable, then the starter electrical cable.
2. Remove cable support and ground cable connection from upper starter stud bolt.
3. Remove starter brace from cylinder block and starter.
4. Remove starter mounting bolts.
5. Remove starter. 
7. Reverse procedure to install.