Radiator Cooling Fan Control Module: Service and Repair

Integrated Relay Control Module

REMOVAL AND INSTALLATION

1.

Remove radiator sight shield.

2.

Disconnect electrical connector. Remove integrated relay control assembly located on radiator support.

3.

Disconnect electric fan connector.

4.

Unbolt fan and shroud assembly from radiator.

5.

Rotate fan and shroud assembly and remove past radiator.

6.

Remove fan U-spring retainer from motor shaft and remove fan.

7.

Unbolt fan motor from shroud.

8.

To install, reverse Steps 1 through 7. Tighten fan retaining screws to 11-14 Nm (97-123 lb-in). Tighten shroud retaining bolts to 2.6-3.7 Nm (23-33
lb-in)
. Tighten shroud retaining nuts to 8-12 Nm (71-106 lb-in).