7. Lubricate the fitting with clean refrigerant oil and assemble the orifice tube kit (with the A/C evaporator core orifice installed) to the condenser to

evaporator tube. Make sure the flow direction arrow is pointing toward the evaporator end of the condenser to evaporator tube, and the taper of
each compressor ring is toward the compression nut.

 Orifice Tube Kit Installed

8. While holding the hex of the tube in a vise, tighten each compression nut to 88-95 Nm (65-70 ft lb) with a crow foot wrench.
9. Assemble the condenser to evaporator tube to the vehicle using new green 0-ring seals lubricated with clean refrigerant oil. Use only the specified

green 0-ring seals at the spring lock coupling.

10. Leak-test, evacuate, and charge the system.
11. Check the system for proper operation.

Fuse HVAC > < Orifice Tube <--> [Expansion Block/Orifice Tube]|Specifications|Page 7454