ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

With Electronic Automatic Temperature Control|Page 7342 > < With Electronic Automatic Temperature Control|Page 7340
Page 6
background image

3. Install the shield and screws.

4. Install the recirculation air duct.

1

Position the recirculation air duct.

2

Install the three screws.

3

Connect the vacuum hose.

5. Install the bracket.

6. Install the blower motor and blower motor speed control as an assembly. Install the screws. Connect the vacuum hose.

With Electronic Automatic Temperature Control|Page 7342 > < With Electronic Automatic Temperature Control|Page 7340