12. Disconnect degas tube from radiator coolant recovery reservoir and lower intake manifold fitting.
13. Remove retaining nut and bolts for upper generator brace and remove brace.
14. Remove engine control sensor wiring bracket from throttle body retaining stud bolt and position engine control sensor wiring out of the way.

15. Remove intake manifold support from the throttle body and RH cylinder head.
16. Loosen and remove the upper intake manifold retaining bolts and stud bolts (note location for installation).