ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporator Case > < Peanut Fitting|Page 9865
Page 3
background image

6. Lubricate male fitting, green O-ring seals and inside of female fitting with clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford

specification WSH-M1C231-B.

7. Install plastic indicator ring into cage opening if indicator ring is to be used.
8. Fit female fitting to male fitting and push with a twisting motion until garter spring snaps over flared end of female fitting.

If plastic indicator ring is used, it will snap out of cage opening when coupling is connected to indicate engagement.

9. If indicator ring is not used, check coupling engagement by making sure the garter spring is over flared end of female fitting.

10. Install clip to spring lock coupling.

Evaporator Case > < Peanut Fitting|Page 9865