ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Locations > < A/C Cycling Switch
Page 1
background image

Refrigerant Pressure Sensor / Switch: Specifications
A/C Pressure Cut-Off Switch

Compressor Control
Open ........................................................................................................................................................................................  2896 kPa (420 psi) Minimum
Close .......................................................................................................................................................................................  1724 kPa (250 psi) Maximum

Fan Control
Open .........................................................................................................................................................................................................  1896 kPa (275 psi)
Close ........................................................................................................................................................................................................  2241 kPa (325 psi)