11. Remove the 2 floorpan bracket nuts.

-

To install, tighten to 3 Nm (27 lb-in).

Vehicles with power liftgate

12. Disconnect the power Liftgate/Trunk Module (LTM) electrical connector.

13. Remove the LTM bolt.

-

To install, tighten to 9 Nm (80 lb-in).

14. Remove the LTM and bracket.

All vehicles

15. Remove the 2 auxiliary duct pin-type retainers and detach the auxiliary ducts.

16. Disconnect the 2 auxiliary climate control housing electrical connectors.

17. Detach the auxiliary blower motor relay pin-type retainer(s).

18. Remove the 3 auxiliary climate control housing bolts.

-

To install, tighten to 6 Nm (53 lb-in).

19. Remove the auxiliary climate control housing.

20. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Add the correct amount of clean PAG oil to the refrigerant system.

21. Fill the engine coolant.

22. Evacuate, leak test and charge the refrigerant system.

Auxiliary Climate Control Housing|Page 5412 > < Auxiliary Climate Control Housing|Page 5410