ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2677 > < Initial Inspection and Diagnostic Overview|Page 2675
Page 5
background image

harness side.

-

Are the resistances less than 5 ohms?

Yes

GO to B4.

No

REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
B4 CHECK FOR CORRECT ABS MODULE OPERATION

-

Disconnect the ABS module connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the ABS module connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new ABS module. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test C: The Instrument Cluster (IC) Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test C: The Instrument Cluster (IC) Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 60, Instrument Cluster for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Normal Operation

The Instrument Cluster (IC) communicates with the scan tool through the High Speed Controller Area Network (HS-CAN) and the Medium Speed
Controller Area Network (MS-CAN). Circuits VDB04 (WH/BU) (HS-CAN +) and VDB05 (WH) (HS-CAN -) provide the HS-CAN connection to the
IC and circuits VDB06 (GY/OG) (MS-CAN +) and VDB07 (VT/OG) (MS-CAN -) provide the MS-CAN connection to the IC. Voltage for the IC is
provided by circuits CBP29 (WH/VT) and 1566 (RD/YE). Circuit GD111 (BK/BU) provides ground.

The IC shares the HS-CAN with the following modules:

-

PCM