To clean the sealing area, use silicone gasket remover and metal surface prep. Failure to follow this procedure can cause future oil leakage.

Apply an 8 mm (0.31 in) bead of Motorcraft High Performance Engine RTV Silicone to the engine front cover-to-RH cylinder head joints.

3. Using a new gasket, install the RH valve cover, bolt and the 10 stud bolts.

-

Tighten in the sequence shown to 10 Nm (89 lb-in).

4. Install the PSP tube bracket on the valve cover stud bolt and install the nut.

-

Tighten to 7 Nm (62 lb-in).

5. Attach all of the wiring harness retainers to the RH valve cover stud bolts.

6. Connect the 3 RH fuel injector electrical connectors.

7. Connect the RH VCT solenoid electrical connector.

8. Connect the RH HO2S electrical connector.

9. Connect the RH CMS electrical connector.

10. Install the RH ignition coils.