ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Heater Core > < Thermostatic Expansion Valve (TXV)|Page 5363
Page 2
background image

2. Remove the 4 cross vehicle beam nuts and remove the beam.

-

To install, tighten to 30 Nm (22 lb-ft).

3. Remove the auxiliary evaporator outlet and inlet line fitting nuts and position the auxiliary lines aside (if equipped).

-

Discard the O-ring seals and gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

4. Remove the Thermostatic Expansion Valve (TXV) fitting nut.

-

Discard the O-ring seals.

-

To install, tighten to 8 Nm (71 lb-in).

5. Remove the 2 TXV bolts.

-

To install, tighten to 8 Nm (71 lb-in).

6. Remove the TXV.

-

Discard the O-ring seals.

7. To install, reverse the removal procedure.

-

Install new O-ring seals and gasket seals.

-

Add the correct amount of clean PAG oil.

8. Evacuate, leak test and charge the refrigerant system.

Heater Core > < Thermostatic Expansion Valve (TXV)|Page 5363