ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Auxiliary Evaporator Outlet and Inlet Line|Page 5393 > < Auxiliary Evaporator Outlet and Inlet Line|Page 5391
Page 3
background image

Removal and Installation

1. With the vehicle in NEUTRAL, position it on a hoist.

2. Recover the refrigerant.

3. Drain the engine coolant.

4. Remove the rear subframe.

5. Remove the front auxiliary evaporator inlet line fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

6. Remove the front auxiliary evaporator outlet line fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

7. Release the 2 front auxiliary heater line heater hose clamps and disconnect the hoses.

8. Remove the LH rear quarter panel moulding.

9. Remove the 3 outer LH rear quarter panel moulding bracket bolts.

10. Remove the 2 inner LH rear quarter panel moulding bracket bolts.

11. Remove the LH rear quarter panel moulding bracket.