ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 5414
Page 3
background image

5. Close the high-side and low-side valves on the R-134a Manifold Gauge Set (not the service gauge port valves) and turn OFF the Vacuum Pump.

6. Observe the low-pressure gauge for 5 minutes to make sure that the system vacuum is held. If vacuum is not held for 5 minutes, leak test the

system, repair the leak and evacuate the system again.

Refrigerant System Charging Using a R-134a Refrigerant Management Machine

NOTE: Ford Motor Company recommends use of a R-134a Refrigerant Management Machine to carry out charging of the refrigerant system. If a
R-134a Refrigerant Management Machine is not available, refrigerant system charging may be accomplished using a separate Automatic Refrigerant
Charging Meter and R-134a Manifold Gauge Set.

NOTE: Leaks in refrigerant system service equipment, hoses or gauges can cause a leak that may be misinterpreted as a problem with the vehicle's
refrigerant system. It is necessary to leak-test all refrigerant system service equipment, hoses and gauges on a weekly basis to verify that no leaks are
present.

1. Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Refrigerant Oil Adding  See:

Service and Repair/Refrigerant Oil Adding.

2. Connect a R-134a Refrigerant Management Machine to the low-side and high-side service gauge port valves following the operating instructions

provided by the equipment manufacturer.

3. Set the refrigerant charge amount, and charge the refrigerant system following the instructions provided by the equipment manufacturer.

Refrigerant System Charging Using a R-134a Manifold Gauge Set and Automatic Refrigerant Charging Meter

NOTE: Ford Motor Company recommends use of a R-134a Refrigerant Management Machine to carry out charging of the refrigerant system. If a
R-134a Refrigerant Management Machine is not available, refrigerant system charging may be accomplished using a separate Automatic Refrigerant
Charging Meter and R-134a Manifold Gauge Set.

NOTE: Leaks in refrigerant system service equipment, hoses or gauges can cause a leak that may be misinterpreted as a problem with the vehicle's
refrigerant system. It is necessary to leak-test all refrigerant system service equipment, hoses and gauges on a weekly basis to verify that no leaks are
present.

1. Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Refrigerant Oil Adding  See:

Service and Repair/Refrigerant Oil Adding.

2. Assemble the R-134a Manifold Gauge Set, Automatic Refrigerant Charging Meter and R-134a supply tank following the Automatic Refrigerant

Charging Meter operating instructions.

3. Charge the refrigerant system following the Automatic Refrigerant Charging Meter operating instructions.

4. If the refrigerant flow stops before the refrigerant charge is complete, start the engine, select MAX A/C operation and allow the refrigerant charge

to complete.

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 5414