Taurus X AWD V6-3.5L (2009)
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.
-------------------------------------------------
D1 CHECK THE DOOR AJAR PIDs
-
Ignition ON.
-
Enter the following diagnostic mode on the scan tool: SJB DataLogger.
-
Check the SJB door ajar switch PIDs (D_DR_SW, P_DR_SW, LRDR_SW and RRDR_SW) while opening and closing all the doors.
-
Do all the door ajar switch PID values agree with the door positions?
Yes
GO to D4.
No
GO to D2.
-------------------------------------------------
D2 CHECK THE DOOR AJAR SWITCH OPERATION
-
Disconnect: Suspect Door Ajar Switch .
-
Do the courtesy lamps illuminate?
Yes
INSTALL a new door ajar switch in question. TEST the system for normal operation.
No
GO to D3.
-------------------------------------------------
D3 CHECK THE DOOR AJAR SWITCH CIRCUIT FOR A SHORT TO GROUND
-
Ignition OFF.
-
Disconnect: SJB C2280c.
-
Measure the resistance between the suspect door ajar switch, harness side and ground as follows:
-
Is the resistance greater than 10,000 ohms?
Yes
GO to D4.
No
REPAIR the circuit in question. TEST the system for normal operation.
-------------------------------------------------
D4 CHECK FOR CORRECT SJB OPERATION
-
Disconnect all the SJB connectors.
-
Check for:
-
corrosion