background image

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

-------------------------------------------------
D1 CHECK THE DOOR AJAR PIDs

-

Ignition ON.

-

Enter the following diagnostic mode on the scan tool: SJB DataLogger.

-

Check the SJB door ajar switch PIDs (D_DR_SW, P_DR_SW, LRDR_SW and RRDR_SW) while opening and closing all the doors.

-

Do all the door ajar switch PID values agree with the door positions?

Yes

GO to D4.

No

GO to D2.

-------------------------------------------------
D2 CHECK THE DOOR AJAR SWITCH OPERATION

-

Disconnect: Suspect Door Ajar Switch .

-

Do the courtesy lamps illuminate?

Yes

INSTALL a new door ajar switch in question. TEST the system for normal operation.

No

GO to D3.

-------------------------------------------------
D3 CHECK THE DOOR AJAR SWITCH CIRCUIT FOR A SHORT TO GROUND

-

Ignition OFF.

-

Disconnect: SJB C2280c.

-

Measure the resistance between the suspect door ajar switch, harness side and ground as follows:

-

Is the resistance greater than 10,000 ohms?

Yes

GO to D4.

No

REPAIR the circuit in question. TEST the system for normal operation.

-------------------------------------------------
D4 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

Initial Inspection and Diagnostic Overview|Page 7712 > < Initial Inspection and Diagnostic Overview|Page 7710