Fuse

-

Wiring, terminals or connectors

-

SJB

PINPOINT TEST H: THE SJB DOES NOT RESPOND TO THE SCAN TOOL

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

-------------------------------------------------
H1 CHECK THE SJB VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

-

Ignition ON.

-

NOTE: Measurements are taken with the fuses installed.

-

Measure the voltage between the SJB fuse 5 (10A) and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to H2.

No

VERIFY the SJB fuse 5 (10A) is OK. If OK, GO to H4. If not OK, Refer to the Wiring Diagrams to identify the possible causes of the short circuit.

-------------------------------------------------
H2 CHECK THE SJB GROUND CIRCUITS FOR AN OPEN

-

Ignition OFF.

-

Disconnect: SJB C2280d.

-

Measure the resistance between the SJB, harness side and ground, as follows:

-

Are the resistances less than 5 ohms?

Yes

GO to H3.