ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Spring Lock Couplings|Page 3273 > < Spring Lock Couplings|Page 3271
Page 1
background image

Fuel Line Coupler: Service and Repair
Quick Connect Coupling

Quick Connect Coupling

Disconnect - Type I

WARNING: Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component.
Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.

WARNING: Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any
fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in
serious personal injury.

WARNING: Before working on or disconnecting any of the fuel tubes or fuel system components, relieve the fuel system pressure to prevent
accidental spraying of fuel. Fuel in the fuel system remains under high pressure, even when the engine is not running. Failure to follow this
instruction may result in serious personal injury.

WARNING: Always disconnect the battery ground cable at the battery when working on an evaporative emission (EVAP) system or
fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in
serious personal injury.

NOTICE: When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the connector
retaining clip area before separating from the tube or damage to the tube or connector retaining clip can occur. Apply clean engine oil to the
end of the tube before inserting the tube into the connector.

NOTICE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is
observed when working with these components or component damage can occur. Always install plugs to any open orifices or tubes.

NOTICE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.

1. If servicing a liquid fuel tube quick connect coupling, release the fuel system pressure. For additional information, refer to Fuel System Pressure

Release  See: Fuel Filter/Fuel Pressure Release/Service and Repair.

2. Disconnect the battery ground cable.

3. NOTE: When reusing liquid or vapor tube quick connect couplings, make sure to use compressed air to remove any foreign material from the

retaining clip area before disconnecting from the tube.

Depress the retainer clip and disconnect the quick connect coupling from the tube.

Connect - Type I

1. NOTE: Apply clean engine oil to the end of the tube and quick connect coupling O-ring seals.

NOTE: Make sure the retainer clip is fully seated and locked onto the tube by pulling on the quick connect coupling.

Install the quick connect coupling onto the tube until fully seated.

Spring Lock Couplings|Page 3273 > < Spring Lock Couplings|Page 3271