ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Control Assembly, HVAC > < Air Conditioning - Approved Flushing Procedures|Page 6778
Page 2
background image

Fig. 3 Condenser assembly removal

4.

Remove four bolts attaching condenser to radiator support, then the condenser, Fig. 3.

5.

Reverse procedure to install. Use new O-rings lubricated with refrigerant oil. Add one ounce of refrigerant oil to new condenser.

6.

Evacuate, charge and leak test system. Check system for proper operation. 

Control Assembly, HVAC > < Air Conditioning - Approved Flushing Procedures|Page 6778