Pressure Regulating Solenoid: Service and Repair
Installation

1. Lubricate EPC solenoid seal and O-ring with a light coating of Motorcraft MERCON(r) Multi-Purpose (ATF) Transmission Fluid XT-2-QDX or

equivalent MERCON(r) approved fluid. MERCON(R) automatic Transmission Fluid is being replaced by MERCON(R) V as a service fluid, as
per TSB 06-14-4. Install electronic pressure (EPC) control solenoid by sliding it into the bore.

2. Install the EPC solenoid bracket. Install bolt and tighten to 11-15 Nm (98-132 in. lbs.). 
3. Install connector to EPC solenoid by pushing connector body in place.
4. Position manual valve detent lever and parking lever actuating rod into case. Parking lever actuating rod must be positioned over parking pawl.
5. Slide manual control lever into case and position through detent. Install nut and tighten to 26-37 Nm (20-27 ft. lbs.). 
6. Install manual lever shaft retaining pin.

7. Install transmission range sensor on manual control lever and two shims, then loosely install bolts.