2. Remove the door trim panel (refer to Operation No. 43 705 0).
CAUTION:
Do not touch the adhesive surface as re‐bonding will be impaired.
3. Locally peel back the door insulation material.
Using a plastic knife, (disposable cutlery) cut through the Butyl strip to enable the foam insulator to be peeled back for access. DO NOT attempt to peel the insulation from the door without cutting the butyl.
4. Remove the remote control fixing screw.
5. Remove the shroud.
6. Align the lock control cable.
1. Displace the plastic outer cable end and blanking piece from the handle housing.
2. Apply light inwards pressure to the control lever when in a locked position to align the inner cable with the release slot.
7. Remove the cable.
Push down on the cable ferrule to disconnect the inner cable and remove the handle assembly.