freightliner Workshop Repair Guides

Freightliner Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 1013 > < Symptom Related Diagnostic Procedures|Page 1011
Page 2
background image

-

Do not exceed the limits shown in the table:
*Ohms cannot be measured if voltage is present. Ohms can be measured only on a non-powered circuit.

-

Voltage between any terminal and ground must not exceed 500 v DC or 500 v peak AC.

-

Use caution when measuring voltage above 25 v DC or 25 v AC.

-

Use the low current shunt to measure circuits up to 10 A. Use the high current clamp to measure circuits exceeding 10 A.

-

When testing for the presence of voltage or current, make sure the meter is functioning correctly. Take a reading of a known voltage or current
before accepting a zero reading.

-

When measuring current, connect the meter in series with the load.

-

Disconnect the live test lead before disconnecting the common test lead.

-

When using the meter function, keep the DRBIII(R) away from spark plug or coil wires to avoid measuring error from outside interference.

Symptom Related Diagnostic Procedures|Page 1013 > < Symptom Related Diagnostic Procedures|Page 1011