freightliner Workshop Repair Guides

Freightliner Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1896 > < Diagram Information and Instructions|Page 1894
Page 3
background image

Testing For A Short To Ground

TESTING FOR A SHORT TO GROUND

1. Remove the fuse and disconnect all items involved with the fuse.
2. Connect a test light or a voltmeter across the terminals of the fuse.
3. Starting at the fuse block, wiggle the wiring harness about six to eight inches apart and watch the voltmeter/test lamp.
4. If the voltmeter registers voltage or the test lamp glows, there is a short to ground in that general area of the wiring harness.

Testing Components For A Short To Ground On A Fuse Powering Several Loads

TESTING COMPONENTS FOR A SHORT TO GROUND ON A FUSE POWERING SEVERAL LOADS

1. Refer to the wiring diagrams and disconnect or isolate all items on the suspected fused circuit.
2. Replace the blown fuse.
3. Supply power to the fuse by turning ON the ignition switch or re-connecting the battery.
4. Start connecting the items in the fused circuit one at a time. When the fuse blows the component with the short to ground has been isolated.

Testing For A Voltage Drop

TESTING FOR A VOLTAGE DROP

1. Connect the positive lead of the voltmeter to the side of the circuit closest to the battery.
2. Connect the other lead of the voltmeter to the other side of the switch, component or circuit.
3. Operate the item.
4. The voltmeter will show the difference in voltage between the two points.

Diagram Information and Instructions|Page 1896 > < Diagram Information and Instructions|Page 1894