freightliner Workshop Repair Guides

Freightliner Workshop Service and Repair Manuals

Continuous Trap Oxidizer, Diesel Emissions|Removal|Page 758 > < Sensor-Exhaust Temperature 1/1|Page 753
Page 1
background image

Continuous Trap Oxidizer: Service and Repair
Removal

REMOVAL

1.   Raise and support vehicle.
2.   Remove solid pressure differential sensor tubing at DPF.
3.   Disconnect and remove DPF temp sensor.
4.   Remove cushion clamp nut at isolator bracket.
5.   Saturate the clamp bolts with heat valve lubricant. Allow 5 minutes for penetration.
6.   Remove catalytic converter to DPF clamp bolt.

7.   Remove DPF (4) and muffler (3) from mounting isolators (1). Remove from vehicle.
8.   Remove band clamp nuts (2) and separate DPF from muffler (3).

Continuous Trap Oxidizer, Diesel Emissions|Removal|Page 758 > < Sensor-Exhaust Temperature 1/1|Page 753