Metro L3-61 1.0L (1990)
Blower Motor: Service and Repair
Fig. 12 Blower Motor Case Attaching Screw Locations
Fig. 13 Blower Motor & Case Assembly
1.
Disconnect battery ground cable.
2.
Remove two screws attaching glove compartment striker to instrument panel.
3.
Remove one screw attaching rear of glove compartment upper panel, then remove upper panel.
4.
Disconnect blower motor and blower resistor electrical connectors.
5.
Disconnect fresh air control cable from blower motor housing.
6.
Remove three blower motor housing attaching bolt, then remove blower motor housing, Fig 12.
7.
Remove air hose, then remove three attaching screws and separate blower motor from housing, Fig. 13.
8.
Reverse procedure to install.