geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Refrigerant Oil|Capacity Specifications|Page 6547 > < A/C - New PAG Oil
Page 1
background image

Refrigerant Oil: Capacity Specifications

Compressor Model ..........................................................................................................................................................................................................  [05]
Oil Charge (FL. Oz.) When Replacing Component

Compressor ......................................................................................................................................................................................................................  [03]

Evaporator ............................................................................................................................................................................................................................  3
Condenser ........................................................................................................................................................................................................................  [07]

Receiver & Dehydrator .....................................................................................................................................................................................................  3.5

[03] Drain oil from old compressor and measure, then drain new compressor. If more than one ounce is drained from old compressor, add same amount

to new compressor. If less than one ounce is drained from compressor, add two ounces.

[05] Nippondenso 10PA15.
[07] Drain oil from old condenser and measure. If more than .5 ounce is drained from old condenser, add same amount to new condenser. If less than .5

ounce is drained from condenser, add .5 ounce.

Refrigerant Oil|Capacity Specifications|Page 6547 > < A/C - New PAG Oil