geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Exhaust Gas Recirculation > < Thermal Vacuum Valve - EVAP|Testing and Inspection
Page 2
background image

Testing EVAP TVV - 54 Degrees C (129 Degrees F)

EVAPORATIVE EMISSION THERMAL VACUUM VALVE CHECK

PRELIMINARY STEP

Drain engine coolant. 

REMOVE OR DISCONNECT

1. Negative (-) battery cable.
2. Two vacuum hoses from Evaporative Emission Thermal Vacuum Valve (EVAP TVV).
3. EVAP TVV from intake manifold.

INSPECT 

EVAP TVV for proper operation using the following steps:
^

Cool EVAP TVV by placing in water and cooling to 35°C (95°F). Check the air does not flow from the upper port to the lower port. If
operation is not as specified, replace EVAP TVV.

^

Heat EVAP TVV by placing in water and heating to 54°C (129°F). Check that air flows from the upper port to the lower port. If operation is
not as specified, replace EVAP TVV.

INSTALL OR CONNECT

1. Apply RTV SILICON SEALANT, GM P/N 105297 or equivalent to two or three threads of EVAP TVV.
2. EVAP TVV to intake manifold.
3. Two vacuum hoses to EVAP TVV.

^

Refill engine coolant to proper level.

4. Negative (-) battery cable. Tighten negative (-) battery cable-to-negative (-) battery terminal retainer to 15 Nm (11 lb. ft.).

Exhaust Gas Recirculation > < Thermal Vacuum Valve - EVAP|Testing and Inspection