geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Actuator|Page 4160 > < Cruise Control Module|Locations|Page 4155
Page 1
background image

Cruise Control Servo: Testing and Inspection
Actuator

Fig. 19 Checking Control Cable Freeplay

1.

Ensure control cable freeplay is less than .39 inch, Fig. 19, adjusting as necessary.

2.

Using a digital multimeter, J43029-A, or equivalent, measure resistance values between terminals 2 and 3, then measure resistance between
terminals 1 and 3.

3.

If resistance is not approximately 30 ohms between terminals 2 and 3, and approximately 68 ohms between terminals 1 and 3, replace actuator.

4.

Disconnect actuator electrical connector.

5.

Connect positive lead from battery to terminals 1 and 2 and the negative lead to terminal 3.

6.

Using a hand held vacuum pump, J23738-A, or equivalent, slowly apply vacuum from 0 to 11.8 inches Hg, ensuring control cable can be pulled
smoothly.

7.

Disconnect terminal 1 and 2, then check control cable returns to original position, and vacuum returns to 0 inches Hg.

8.

If results are not as indicated, replace actuator.

Actuator|Page 4160 > < Cruise Control Module|Locations|Page 4155