Distributor: Testing and Inspection

Measure

Tool Required:
J39200 Digital Multimeter

NOTICE: The term "cold" refers to temperature ranging from -10° C (14° F) to 50°C (104° F). The term "hot" refers to temperature ranging from 50° C

(104° F) to 100° C (212° F).

Measuring Camshaft Position Sensor Resistance

1.

The resistance of distributor connector C1 when cold, between terminals 3 and 6, using a J39200. If the camshaft position (CMP) sensor resistance
is not between 185 and 275 ohms, replace the distributor housing.

2.

The resistance of distributor connector C1 when cold, between terminals 2 and 5. using a J39200. If the CMP sensor resistance is not between 370
and 550 ohms. replace the distributor housing.

3.

The resistance of distributor connector C1 when hot, between terminals 3 and 6, using a J39200. If the CMP sensor resistance is not between 240
and 325 ohms. replace the distributor housing.

4.

The resistance of distributor connector C1 when hot, between terminals 2 and 5. using a J39200. If the CMP sensor resistance is nor between 475
and 650 ohms, replace the distributor housing.

Distributor, Ignition|Locations|Page 779 > < Distributor, Ignition|Locations|Page 777