geo Workshop Repair Guides

Geo Prizm L4-1800cc 18L DOHC Workshop Service and Auto Repair Manuals

Distributor Disassembly & Assembly|Page 784 > < Distributor Disassembly & Assembly|Page 782
Page 3
background image

Measuring Camshaft Position Sensor Resistance

1.

The resistance of distributor connector C1 when cold, between terminals 3 and 6, using a J39200. If the camshaft position (CMP) sensor resistance
is not between 185 and 275 ohms, replace the distributor housing.

2.

The resistance of distributor connector C1 when cold, between terminals 2 and 5. using a J39200. If the CMP sensor resistance is not between 370
and 550 ohms. replace the distributor housing.

3.

The resistance of distributor connector C1 when hot, between terminals 3 and 6, using a J39200. If the CMP sensor resistance is not between 240
and 325 ohms. replace the distributor housing.

4.

The resistance of distributor connector C1 when hot, between terminals 2 and 5. using a J39200. If the CMP sensor resistance is nor between 475
and 650 ohms, replace the distributor housing.

Measuring Air Gap

5.

Air gap between the signal rotor and camshaft position (CMP) sensor. If the air gap is not between 0.2 - 0.4 mm (0.008 - 0.016 inch), replace the
distributor housing.

Distributor Disassembly & Assembly|Page 784 > < Distributor Disassembly & Assembly|Page 782