Oxygen Sensor Circuit

CIRCUIT DESCRIPTION:

The oxygen sensor (02S), produces a voltage that varies between .1 volt and .9 volt under normal operating conditions. The ECM monitors this voltage
and determines if the exhaust is lean or rich. If the voltage input at the ECM is about .1 volt, the exhaust is lean, and if the voltage input is about .9 volt,
the exhaust is rich. If the (O2S) is below 360°C (600°F) it is like an open circuit and will not produce a voltage. This will cause "OPEN LOOP"
operation.

Code 21 will set if:

^

Engine operating temperature greater than 80°C (176°F).

^

O2S voltage steady between .35 V and .70 V.

^

Engine speed > 1500 rpm.

^

All conditions met for 60 seconds.

 
TEST DESCRIPTION:  The numbers below refer to circled numbers on the diagnostic chart.

1.

This checks to see if the O2S is faulty.

2.

This checks for an open in BLK wire between O2S and PCM.

3.

This checks for an open in BRN wire between O2S and G106.

4.

This checks for a short to ground in BLK wire between O2S and PCM, an open in BRN wire to the O2S on federal emissions vehicles and for a
faulty PCM.

DIAGNOSTIC AIDS:

Normal voltage on the (02S) input wire varies between 100 mV and 1000 mV (0.1 and 1.0 volt), while in "CLOSED LOOP."