Refrigerant Pressure Sensor / Switch: Service and Repair

Case Temperature Switch And High-Pressure Relief Valve

Remove or Disconnect

1. Battery negative (-) cable.
2. Compressor from vehicle.
^

Mount compressor into vise.

3. Lead wire retaining clip.
4. Magnetic clutch electrical connector.
^

Unscrew and remove case temperature switch from compressor (Figure 17).

Install or Connect

1. Case temperature switch to compressor.

Tighten
^

Case temperature switch to 11 N.m (97 lb. in.).

2. Magnetic clutch electrical connector.
3. Lead wire retaining clip.
4. Compressor to vehicle.
5. Battery negative (-) cable.