geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Power Steering Pressure Switch > < Oxygen Sensors - Silica Contamination|Page 1647
Page 1
background image

Oxygen Sensor: Service and Repair

The oxygen sensor uses a permanently attached pigtail and connector. This pigtail should not be removed from the oxygen sensor. Damage or removal of
the pigtail or connector could affect proper operation of the oxygen sensor, Take care when handling the oxygen sensor. The in-line electrical connector
and louvered end must be kept free of grease, dirt or other contaminants. Also, avoid using cleaning solvents of any type. DO NOT drop or roughly
handle the oxygen sensor. The oxygen sensor may be difficult to remove when engine temperature is below 48°C (120°F). Excessive force may damage
threads in exhaust manifold or exhaust pipe.

REMOVAL

1.

Remove negative battery cable.

2.

Disconnect electrical connector.

3.

Carefully back out oxygen sensor.

INSTALLATION

A special anti-seize compound is used on the oxygen sensor threads. The compound consists of a liquid graphite and glass beads. The graphite will burn
away, but the glass beads will remain, making the sensor easier to remove. New or service sensors will already have the compound applied to the threads.
If a sensor is removed from an engine, and is to be re-installed, the threads must have anti-seize compound applied before re-installation.

1.

Coat threads of oxygen sensor with anti-seize compound P/N 5613695 or equivalent if necessary.

2.

Install sensor, and torque to 41 N-m (30 ft. lbs.).

3.

Connect electrical connector.

4.

Connect negative battery cable.

Power Steering Pressure Switch > < Oxygen Sensors - Silica Contamination|Page 1647