Fig. 6  Wire Size Conversion Table

3. Strip the Insulation - and when replacing a wire, use a wire of the same size as the original wire or larger. The schematics list wire size in metric

units. See table, for the commercial (AWG) wire sizes that can be used to replace each metric wire size. Each AWG size is either equal to or larger
than the equivalent metric size. To find the correct wire size either find the wire on the schematic and convert the metric size to the AWG size, or
use an AWG wire gage. If you aren't sure of the wire size, start with the largest opening in the wire stripper and work down until a clean strip of
the insulation is removed. Be careful to avoid nicking or cutting any of the wires.

Fig. 8  Crimping the Splice Clip