Tracker 4x2 L4-1.6L SOHC TBI (1994)
Figure 14
Figure 15
Figure 16
3. If terminal is to be re-used, re-form locking tang (see Figures 12 through 16).
4. Making repair when using a new terminal:
a. Slip cable seal away from terminal (if seal exist).
b. Cut wire as close to terminal as possible.
c. Slip a new cable seal onto wire (if necessary).
d. Strip 5 mm (3/16") of insulation from wire.
e. Crimp a new terminal to the wire.
f.
Solder with rosin core solder.
g. Slide cable seal toward terminal (if equipped with seal).
h. Crimp cable seal and insulation (if equipped with seal).
i.
Apply grease to connectors outside passenger compartment where connector was originally equipped with grease.