Positive Crankcase Ventilation Valve: Service and Repair

PCV VALVE REPLACEMENT PROCEDURE

MAINTENANCE PRECAUTION

An engine which is operated without any crankcase ventilation can be damaged. Therefore, it is important to replace the Positive Crankcase
Ventilation (PCV) valve at scheduled maintenance intervals.

VISUAL INSPECTION

Periodically inspect the hoses and clamps and replace any showing signs of deterioration.

REMOVE OR DISCONNECT

1. Negative (-) battery cable.
2. Three bolts and throttle cover.
3. One clamp and PCV hose from PCV valve.
4. Rubber insulator from PCV valve.
5. PCV valve from intake manifold.

INSTALL OR CONNECT

1. PCV valve to intake manifold.
2. Rubber insulator to PCV valve.
3. PCV hose to PCV valve; secure with one clamp.
4. Throttle cover; secure with three bolts. Tighten throttle cover bolts to 15 Nm (11 lb. ft.).
5. Negative (-) battery cable. Tighten negative (-) battery cable-to-negative (-) battery terminal retainer to 15 Nm (11 lb. ft.).