Tracker 4x4 L4-1.6L SOHC TBI (1994)
Fig. 12 Servo Terminals 1, 2, 3, & 4 Location.
5. Connect terminals 2 and 3 to battery positive and terminals 1 and 4 to ground, Fig. 12.
6. Ensure motor pulls cable actuating lever to the fully open position.
7. Disconnect probe from terminal 3, cable should return quickly, allowing servo lever to return to fully closed position.
8. Connect battery positive to terminal 3 and battery ground to terminal 1.
9. Ensure clutch operation maintains servo cable position at this time.