geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Catalytic Converter|Specifications|Page 2377 > < Catalytic Converter|Specifications|Page 2375
Page 1
background image

Catalytic Converter: Description and Operation

Three Way Converter Cutaway

PURPOSE

Neutralize carbon monoxide, hydrocarbons and oxides of nitrogen in the exhaust gases leaving the engine.

LOCATION

In the exhaust piping.

OPERATION

This is achieved by converting carbon monoxide and hydrocarbons to carbon dioxide and water. Also, oxides of nitrogen are converted to nitrogen
and water. This chemical conversion is caused by the platinum/rhodium metals in the catalytic converter. The noble metal content is about two
grams of platinum/rhodium.

The effective conversion of pollutants begins at an operating temperature of about 250°C (450°F). The ideal operating temperature is 400°C-800°
C (750°F-1500°F). Engine malfunctions, for example misfires, can cause the temperature of the converter to increase to more than 1400°C (2500°
F). Such temperatures lead to the complete destruction of the converter through the melting of the substrate material.

Using leaded fuel will damage the converter and quickly render it ineffective, by coating the noble metals with lead deposits.

Catalytic Converter|Specifications|Page 2377 > < Catalytic Converter|Specifications|Page 2375