Impact Sensor: Description and Operation
Arming Sensor

The arming sensor is a protective switch located in the power side of the deployment loop. It is calibrated to close at low level speed changes. This
ensures that the inflator module is connected directly to the 36 Volt Loop Reserve (VLR) output of the DERM when either of the discriminating sensors
close.