geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 2689 > < Diagram Information and Instructions|Page 2687
Page 14
background image

Figure 17

To re-use a terminal or lead assembly, see Splicing Copper Wire. Be sure to keep cable seal (if equipped) on terminal side of splice.

5. Insert lead from the back until it catches.

Figure 18

Figure 19

6. Install TPA's, CPA's and/or secondary locks, if equipped (see Figures 18 & 19).

Splicing Copper Wire Using Crimp and Seal Splice Sleeves

PROCEDURE

Crimp and Seal splice sleeves may be used on all types of insulation except tefzel and coaxial to form a one to one splice. They are to be used
where there are special requirements such as moisture scaling. (Crimp and Seal splice sleeves are included in the GM J 38125-A Terminal Repair
Kit.)
1. Open the Harness - by removing the tape. To avoid wire insulation damage, use a sewing "seam ripper" to cut open the harness (available

from sewing supply stores). The Crimp and Seal splice sleeves may be used on all types of insulation except tefzel and coaxial and may only
be used to form a one to one splice.

2. Cut the Wire - cutting as little wire off the harness as possible. You may need the extra length of wire later if you decide to cut more wire to

change the location of a splice. You may have to adjust splice locations to make certain that each splice is at least 40 mm (1.5 in.) away from
other splices, harness branches or connectors. This will help prevent moisture from bridging adjacent splices and causing damage.

Diagram Information and Instructions|Page 2689 > < Diagram Information and Instructions|Page 2687