geo Workshop Repair Guides

Geo Workshop Service and Repair Manuals

Arming Sensor|Page 5808 > < Arming Sensor
Page 1
background image

Impact Sensor: Description and Operation
Discriminating Sensors

There are two discriminating sensors in the air bag system. They are wired in parallel on the low (ground) side of the deployment loop. These sensors are
calibrated to close with speed changes severe enough to warrant deployment.
A diagnostic resistor is connected in parallel with the switch contacts within each of the discriminating sensors. These parallel resistors supply the ground
path for the current passing through the deployment loop during normal operation. This current flow results in voltage drops across each component in
the deployment loop. The DERM monitors these voltage drops to detect malfunctions.

Arming Sensor|Page 5808 > < Arming Sensor