Air Door Actuator / Motor: Description and Operation

The Valves which control the flow of air through the Heater and A/C Module are positioned by electric Motors. There is one Motor and one Position
Potentiometer for each Valve except the Recirculation Valve which does not contain a potentiometer. The Position Potentiometer indicates the position
of the Valve at any time to the Heater and A/C Controller by means of a voltage level.

There are two drive circuits for each Motor in the Controller which can operate the Motors in either direction. When any Motor is to operate, one of the
drivers supplies approximately 7.5 volts to one side of the Motor depending on the direction it is to run.

The Recirculation Valve is normally in the position that allows outside air to enter the system. When RECIRC is selected, the Motor changes to the
RECIRC Air position. If RECIRC is selected again or defrost is selected, the Controller will provide voltage to position the Motor back to the outside air
position. Since there is no potentiometer on the Recirculation Valve, the Controller drives the motor for 22 seconds to ensure the proper position is
attained.

The Temperature Valve Motor positions the Temperature Valve according to the Temperature setting of the Heater and A/C Controller. For the full Cold
temperature setting, the Temperature Valve is in the cold position and the Temperature Valve Potentiometer returns about 4.0 volts to the Heater and
A/C Controller. As the temperature setting is changed to full HOT, the Temperature Valve is moved to the warm positions, and the potentiometer output
rises to about 0.5 volts. For a temperature setting in the mid range, the Temperature Valve is positioned to a point where the potentiometer output is the
same as the preprogrammed value for the selected setting.

The Mode Valve Motor operates in a manner similar to that for the Temperature Valve and is positioned according to the Mode selected. For full A/C,
the potentiometer output is about 0.2 volt and for full DEFROST, the output is about 4.8 volts. In the Heat Mode, the potentiometer output is about 2.5
volts.

Should any of the Motors stall when changing a Valve location, voltage is removed by the Heater and A/C Controller after 45 seconds to protect the
Motor. This sequence will be repeated each time there is a change in the Mode setting.