gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

With A-6 Compressor|Page 7752 > < With A-6 Compressor|Page 7750
Page 4
background image

Install or Connect

1. Follow applicable on-vehicle procedures.

2. To Leak Test, install leak Test Fixture J 9625-A (Fig. 30) on rear head of compressor and connect gage charging lines and J 38100-C Refrigerant

Recovery System. Pressurize suction and high-side of compressor with Refrigerant-12 vapor to drum pressure. Temporarily install the shaft nut
and turn compressor shaft in normal direction of rotation several times by hand. Leak test the seal area and correct any leak found. Recover the
refrigerant. Remove shaft nut.

With A-6 Compressor|Page 7752 > < With A-6 Compressor|Page 7750