A/C Coupler O-ring: Description and Operation
General Information

Install new approved service replacement air conditioning O-ring(s) and flat washers whenever a joint or fitting is disassembled.
Some vehicles use flat sealing washers and O-ring(s) to seal the refrigerant system. The flat washers are used on block fittings of refrigerant components.
The O-ring(s) is used to seal the refrigerant tubes.

The O-ring fitting consists of:

-

An aluminum alloy, externally threaded fitting which is welded to an aluminum tube.

-

A free-spinning internally threaded nut.

-

An aluminum tube end which accommodates the O-ring(s).

Verify that the flat washers or O-ring(s) have not been damaged prior to installation. Replace damaged parts.

Coat O-ring(s) and flat washers with the approved refrigerant oil.
Failure to use the proper service replacement parts and procedures may result in a leak.