gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Variable Valve Timing Actuator|Diagrams|Page 3421 > < Variable Valve Timing Actuator|Diagrams|Page 3419
Page 1
background image

Variable Valve Timing Actuator: Service and Repair

Exhaust Camshaft Position Actuator Replacement 

^

Tools Required
-

EN-44217-45 Chain Holding Tool

-

J 44217 Timing Chain Retention Tool

-

J 44221 Camshaft Holding Tool

-

J 45059 Angle Meter

Removal Procedure

1. Remove the camshaft cover. 
2. Ensure the exhaust Camshaft Position (CMP) actuator is functioning properly. 
3. Remove the exhaust Camshaft Position (CMP) sensor.
4. Remove the intake Camshaft Position (CMP) sensor. 
5. Rotate the crankshaft in the engine rotational direction clockwise, until the #1 piston is at Top Dead Center (TDC) on the compression stroke.

The word Delphi on the exhaust camshaft position actuator will be parallel with the cylinder head to cam cover mating surface.

6. Using the timing mark on the exhaust camshaft position actuator sprocket as a reference, make a mark on the timing chain link adjacent to it.

Caution:  Defer to Camshaft Holding Tool Caution in Service Precautions.

7. Install the J 44221 to the rear of the camshafts.

Variable Valve Timing Actuator|Diagrams|Page 3421 > < Variable Valve Timing Actuator|Diagrams|Page 3419