gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4988 > < Diagram Information and Instructions|Page 4986
Page 3
background image

3. Remove the insulation.
4. For WeatherpackTM terminals only, align the seal with the end of the cable insulation.
5. Position the strip in the terminal.

For WeatherpackTM terminals, position the strip and the seal in the terminal.

6. Hand crimp the core wings.
7. Hand crimp the insulation wings.

For WeatherpackTM terminals, hand crimp the insulation wings around the seal and the cable.

8. Solder all of the hand crimp terminals.

Micro-Pack 100 Terminal Repair

NOTE:  Use the Connector Test Adapter kit J 35616-/ for any test that requires probing the following items:
^

The PCM harness connectors

^

The electrical center fuse/relay cavities

^

The component terminals

^

The component harness connector

Using this kit will prevent damage caused by the improper probing of connector terminals.

Use care when probing connectors and replacing terminals. A short between opposite terminals may damage components. Use jumper wires
between connectors when testing circuits. DO NOT probe through WeatherpackTM seals. The J 35616 connector test adapter kit is the only
recommended method of probing the following components:
^

Connectors

^

Terminals

^

Fuse blocks

^

Relay blocks
The J 35616 connector test adapter kit contains an assortment of flexible connectors used in order to probe the components listed above.

Open circuits may be difficult to locate visually because oxidation or terminal misalignment are hidden by the connectors. Wiggling a connector
on a sensor or in the wiring harness may temporarily correct the open circuit. Intermittent problems may be caused by oxidized or loose
connections. Verify the type of connector/terminal before performing any connector repair or terminal repair.

Terminal Position Assurance Locks

The Terminal Position Assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Weather Pack Connectors

The following is the proper procedure for the repair of Weather Pack Connectors.

^

Separate the connector halves (1).

^

Open the secondary lock. A secondary lock aids in terminal retention and is usually molded to the connector (1).

^

Grasp the wire and push the terminal to the forward most position. Hold the wire in this position.

Diagram Information and Instructions|Page 4988 > < Diagram Information and Instructions|Page 4986