Security Data

Range:  OFF/ IDLE/ DISARMED/ READY TO ARM/ ARM INITIATED/ ARM DELAY/ ALARM/ARMED
The state that displays refers to the state of the content theft system.

OFF STATE displays when ignition 1 is ACTIVE and All of the doors, including the rear glass. are closed.

IDLE STATE displays when ignition 1 is ACTIVE and under the following conditions:

^

Any door is open.

^

The rear glass is open.

DISARM STATE displays ignition 1 transforms from ACTIVE to INACTIVE and under the following conditions:

^

All of the doors are closed.

^

The rear glass is closed.

READY TO ARM STATE displays when ignition 1 transforms from ACTIVE to INACTIVE and under the following conditions:

^

Any door is open.

^

The rear glass is open.

ARM INITIATED STATE displays when ignition 1 is INACTIVE and under the following conditions:

^

All of the doors are locked.

^

The rear glass is closed.

^

Any door is open.

^

The rear glass is open.

ARM DELAY STATE displays when ignition 1 is INACTIVE and under the following conditions:

^

The vehicle is in the armed state.

^

All of the doors are closed.

^

The rear glass is closed.

ARMED STATE displays when the vehicle is in the ARM DELAY state and all of the inputs are monitored in order to determine whether to alarm or
disarm the system. In the ARM DELAY state, ignition 1 is INACTIVE, and all of the doors and the rear glass are closed.

ALARM STATE displays when the vehicle is in the ARMED STATE and the system detects a violation on any of the inputs being monitored.

Content Theft Lamp

Initial Inspection and Diagnostic Overview|Page 484 > < Initial Inspection and Diagnostic Overview|Page 482