gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

A/T - Fluid Oil Cooler Flush|Page 7168 > < A/T - Fluid Oil Cooler Flush|Page 7166
Page 1
background image

Transmission Cooler: Service and Repair

^

Tools Required
-

J 35944- A Oil Cooler and Line Flusher

-

J 35944 - 20 Cooler Flushing Fluid

A/T OIL COOLER FLUSHING

PREPARATION 

NOTICE: 
^

Whenever you remove the transmission for service, you must perform the automatic transmission oil cooler flushing procedure in order to remove
the existing fluid which may be contaminated. This will prevent contamination of the new fluid. You must perform the flushing procedure after the
installation of the overhauled or replacement transmission.

^

Only use J 35944 - 20 Cooler Flushing Fluid with the J 35944-A Oil Cooler and Line Flusher. Use of any other fluid can result in damage to the
tool, damage to the automatic transmission oil cooler components, or improper flushing of the cooler. Do not reconnect the oil cooler pipes after
you reinstall the overhauled or service replacement transmission in the vehicle.

1. Remove the fill cap on J 35944-A.
2. Fill the can with 0.6 Liter (20-21 Ounces) of J 35944 - 20, or equivalent, cooler flushing fluid. Do not overfill. If you overfill, the tool will need

recharging with air before the backflush. Follow the manufacturer's suggested procedures for proper handling of the solution.

3. Secure the fill cap, and pressurize the flusher with shop air to 550-700 kPa (80-100 psi).

NOTICE:  Shop air supply must be equipped with a water/oil filter, and pressure should not exceed 825 kPa (120 psi). Failure to use a water/oil
filter can allow residual moisture to cause corrosion of components. Excessive air pressure can cause damage to components.

4. Connect the discharge hose to the transmission end of the oil cooler pipe that goes to the bottom fitting at the radiator.
5. Clip the discharge hose to the oil drain container.
6. Mount the flushing tool to the undercarriage of the vehicle with the hook provided.
7. Connect the hose from the flushing tool to the remaining oil cooler pipe.
8. With the water valve on the tool in the OFF position, connect the water hose from the water supply to the tool.
9. Turn ON the water supply at the faucet.

INITIAL FLUSHING PROCEDURE 

1. Switch the water valve on the tool to the ON position. Allow the water to flow through the oil cooler for 10 seconds in order to remove the

transmission fluid in the system.

NOTICE:  If water does not flow through the oil cooler (system is completely plugged), do not continue the flushing procedure, or damage to the
tool or components could result. Turn the water OFF immediately. Inspect the pipes and the cooler for restrictions. Replace the oil pipe(s) and/or
the oil cooler.

2. Switch the water valve on the tool to the OFF position. Clip the discharge hose onto a 5 gallon pail with a lid. If there is no lid, place a shop towel

over the end of the hose in order to prevent splash. The discharge will foam vigorously when you introduce solution into the water stream.

3. Switch the water valve on the tool to the ON position. Depress the trigger that mixes the flushing solution into the water flow. Use the bale clip on

the handle in order to hold down the trigger.

4. Flush the oil cooler with water and solution for 2 minutes. During the flush, attach the air supply to the air valve on the tool for 3 to 5 seconds after

every 15 to 20 second interval in order to create a surging action.

5. Release the trigger. Switch the water valve on the tool to the OFF position.
6. Disconnect both hoses from the oil cooler pipes.

BACKFLUSH PROCEDURE 

^

Connect the hoses to the oil cooler pipes opposite from the initial flush in order to perform a backflush.

^

Switch water valve on the tool to the ON position. Depress the trigger in order to mix the flushing solution with the water flow. Use the bale clip
on the handle to hold down the trigger.

^

Flush the oil cooler with water and solution for 2 minutes. During this flush, attach the air supply to the air valve on the tool for 3 to 5 seconds
after each 15 to 20 second interval in order to create a surging action.

^

Release the trigger. Allow water only to rinse the oil cooler for 1 minute.

^

Switch the water valve on the tool to the OFF position.

^

Turn the water supply OFF at the faucet.

^

Attach the air supply to the air valve on the tool. Dry out the system with air for at least 2 minutes. Dry out the system longer than 2 minutes, if
moisture from the oil cooler line discharge hose is visible. If available, use an air chuck clip to secure the air chuck onto the air valve for ease of
operation.

^

Connect the cooler feed pipe to the transmission.

IMPORTANT:  The top fitting at the transmission is the cooler return. The bottom fitting at the transmission is the cooler feed.

A/T - Fluid Oil Cooler Flush|Page 7168 > < A/T - Fluid Oil Cooler Flush|Page 7166