Envoy 2WD V8-5.3L (2007)
Important: The new actuator is in Bi-Level mode. Place the door in the middle of the travel position before you install the actuator.
1. Install the mode actuator (1).
Notice: Refer to Fastener Notice.
2. Install the screws to the mode actuator (1).
Tighten the screws to 1.9 N.m (18 lb in).
3. Install the left hand floor duct.
4. Install the left side sound insulator screws.
5. Recalibrate the mode actuator. Refer to Actuators Recalibration (Auxiliary HVAC) Actuators Recalibration (Primary) See: Testing and
Inspection/Programming and Relearning See: Testing and Inspection/Programming and Relearning
Recirculation Actuator Replacement
Recirculation Actuator Replacement
Removal Procedure
1. Remove the HVAC module assembly.
2. Remove the air inlet assembly screws.
3. Remove the air inlet assembly.
4. Remove the recirculation actuator screws.
5. Remove the electrical connector from the recirculation actuator.
6. Remove the recirculation actuator.
Installation Procedure