VEHICLE DATA RECORDER

The J 42598 is connected to the data link connector (DLC) and sent with the customer. The J 42598 captures data for later retrieval and analysis by the
technician. Refer to the vehicle data recorder user instructions for more information.

Testing For a Short To Voltage

TESTING FOR A SHORT TO VOLTAGE

NOTE:  Refer to Test Probe Notice in Service Precautions.

The following procedure tests for a short to voltage in a circuit.
1. Set the rotary dial of the DMM to the V (DC) position.
2. Connect the positive lead of the DMM to 1 end of the circuit to be tested.
3. Connect the negative lead of the DMM to a good ground.
4. Turn ON the ignition and operate all accessories.
5. If the voltage measured is greater than 1 volt, there is a short to voltage in the circuit.

Testing for Continuity

TESTING FOR CONTINUITY

NOTE:  Refer to Test Probe Notice in Service Precautions.

The following procedures verify good continuity in a circuit.

With a DMM
1. Set the rotary dial of the DMM to the ohm position.
2. Disconnect the power feed (i.e. fuse, control module) from the suspect circuit.
3. Disconnect the load.
4. Press the MIN MAX button on the DMM.
5. Connect one lead of the DMM to one end of the circuit to be tested.
6. Connect the other lead of the DMM to the other end of the circuit.
7. If the DMM displays low or no resistance and a tone is heard, the circuit has good continuity.

With a Test Lamp

IMPORTANT:  Only use the test lamp procedure on low impedance power and ground circuits.

1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Connect 1 lead of the test lamp to 1 end of the circuit to be tested.
4. Connect the other lead of the test lamp to battery positive voltage.
5. Connect the other end of the circuit to ground.
6. If the test lamp illuminates (full intensity), then the circuit has good continuity.

Testing For Electrical Intermittents

TESTING FOR ELECTRICAL INTERMITTENTS

Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching
the test equipment.

-

Testing for Short to Ground

-

Testing for Continuity

-

Testing for a Short to Voltage

If the fault is not identified, perform the procedure below using the MIN MAX feature on the J 39200 DMM. This feature allows you to manipulate the
circuit without having to watch the J 39200. The J 39200 will generate an audible tone when a change is detected.

IMPORTANT:  The J 39200 must be used in order to perform the following procedure since the J 39200 can monitor current, resistance or voltage
while recording the minimum (MIN), and maximum (MAX) values measured.

1. Connect the J 39200 to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other.
2. Set the rotary dial of the J 39200 to the V (AC) or V (DC) position.
3. Press the range button of the J 39200 in order to select the desired voltage range.
4. Press the MIN MAX button of the J 39200. The J 39200 displays 100 ms RECORD and emits an audible tone (beep).