gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Service and Repair
Page 2
background image

Tighten the nut to 28 N.m (21 lb ft).

6. Connect the compressor discharge hose (2) to the condenser (4).
7. Install the retaining nut (1) to the compressor discharge hose (2) at the condenser (4).

Tighten the nut to 28 N.m (21 lb ft).

8. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
9. Leak test the fittings of the components using J 39400-A.

Control Assembly, HVAC > < Condenser HVAC|Service and Repair